Blog Archives

CIRCLY 6.0 Fatal Error Number 9608 – Analysis by numerical engine terminated with fatal error

When you click the “Run Analysis” button, CIRCLY 6.0 uses CIRCLY32.exe to perform the numerical analysis. You are welcome to send your data files so that we can diagnose the problem. Click . The data folder will be shown in the “Data Path” field. By default this will be “C:UsersPublicDocumentsMincad SystemsCIRCLY6data”. Email the .cls and .sto files for the job that is giving the error and the database files LAYERS6.CMDB and LOADS6.CMDB.…

Error Number: 9201 – Hardware Lock has not been activated to run this CIRCLY Version

A. If you have purchased a new licence for CIRCLY 5.0 or later: Please contact Mincad Systems or your local agent to arrange a replacement for your Hardware Lock. B. If you have purchased an upgrade from an earlier version of CIRCLY: You must key in a special activation code to set the Hardware Lock to run this CIRCLY Version. Make sure you have your activation code handy before proceeding. Before doing this you must have installed the Sentinel System Driver (click here for instructions) AND CIRCLY the first time. The Licence Activation Key provided by Mincad Systems will be of the form: V1-HIP1-26719-REN-70611-COMI-7146 Copy the key to the Windows clipboard (by highlighting it and then Control+C). Make sure your CIRCLY/APSDS Hardware Lock…

How do I transfer my CIRCLY 5.1 files to another PC?

To find out what data folder is currently being used (for either PC): Click . The data folder will be shown in the “Data Path” field. By default this will be “C:UsersPublicDocumentsMincad SystemsCIRCLY5data”. To transfer your CIRCLY 5.1 files to another PC: Make sure all instances of CIRCLY are closed. Copy all the files. Of course, if the destination PC has important CIRCLY data you should back up those files first.…

What CIRCLY 5.1 files do I need to backup?

To find out what data folder is currently being used: Click . The data folder will be shown in the “Data Path” field. By default this will be “C:UsersPublicDocumentsMincad SystemsCIRCLY5data”. To backup your data: At the very minimum you only need to back-up all the *.cls files and the database files LAYERS.MDBand LOADS.MDB. There is only one possible catch. CIRCLY is designed to use the latest (and only the latest) versions of the relevant data from the databases when you run an analysis. If you change ANY of the data that was used by previously run jobs, if you run those jobs again they will use the latest data, not the historical data. This is by design. To ensure that you can check the actual data that…

What HIPAVE 5.0 files do I need to backup?

To find out what data folder is currently being used: Click . The data folder will be shown in the “Data Path” field. By default this will be “C:UsersPublicPublic DocumentsMincad SystemsHIPAVE5data”. To backup your data: At the very minimum you only need to back-up all the *.cls files and the database files LAYERS.MDB and LOADS.MDB. There is only one possible catch. HIPAVE is designed to use the latest (and only the latest) versions of the relevant data from the databases when you run an analysis. If you change ANY of the data that was used by previously run jobs, if you run those jobs again they will use the latest data, not the historical data. This is by design. To…